Consumer Notices

Recalls on SupCo SCM Surge Protectors

Square D QO Plug-On Neutral Load Centers

Square D QO Plug-On Neutral Load Centers

 "You may have purchased or had installed one or more of the above referenced SCM Devices from SUPCO. SUPCO distributed the SCM Devices from 2010 until July, 2014... There have been claims that the SCM Devices have caused fire damage to some homes on which they were installed. " https://www.supco.com/web/supco_live/test/surge.html

We recommend contacting your local HVAC contractor to confirm and replace these defective devices.

Square D QO Plug-On Neutral Load Centers

Square D QO Plug-On Neutral Load Centers

Square D QO Plug-On Neutral Load Centers

 "In 2022, Schneider Electric recalled approximately 1.4 million Square D QO Plug-On Neutral Load Centers (also known as load centers, breaker boxes, and electrical panels) manufactured between February 2020 and January 2022 due to a potential fire hazard stemming from overheating." https://www.cpsc.gov/Recalls/2022/Schneider-ElectricTM-Recalls-1-4-Million-Electrical-Panels-Due-to-Thermal-Burn-and-Fire-Hazards?fbclid=IwAR2cMhoOYju6DNpd73J6IKOffv_6VOzb0e0b4lr40ICuRYA6PGHQneGwXsA

https://www.se.com/us/en/work/products/local/safety-notices/2022/qo-pon-loadcenters/

Federal Pacific Electrical Panels

Square D QO Plug-On Neutral Load Centers

Federal Pacific Electrical Panels

Research indicates that certain FPE circuit breakers may be susceptible to issues that could result in failures, inadequate protection of circuits, and more severe concerns such as fire hazards and electrocution. While the Consumer Product Safety Commission has not formally recalled these products, it is important to note that the panel in question is outdated and the manufacturer is no longer in operation. While we are unable to categorically label this panel as defective, we recommend consulting a qualified electrical contractor to obtain their professional assessment for your peace of mind.

Sylvania-Zinsco Electrical Panels

Sylvania-Zinsco Electrical Panels

Federal Pacific Electrical Panels

Zinsco electrical panels are known to pose a potential fire-hazard, and it is recommended to have them assessed or replaced by a qualified electrician. Zinsco panels can typically be recognized by a blue and silver "Zinsco" label located inside the panel, along with an embossed "Magnetrip" label on the upper part of the panel face.

Challenger Breakers

Sylvania-Zinsco Electrical Panels

Challenger Breakers

The circuit breakers on Challenger panels have been observed to overheat and may cause scalding on the bus bars. The identification of a Challenger panel can be confirmed by the sticker located on the rear right, in addition to the labels on the breakers. During a home inspection, a home inspector is generally required to report the type of panel present as a defect.

Pushmatic Breakers

Sylvania-Zinsco Electrical Panels

Challenger Breakers

Unlike modern electrical panels that utilize lever-style breakers which toggle between "ON" and "OFF," Pushmatic breakers operate with a push-button mechanism. Each breaker requires manual engagement to reset or deactivate. Additionally, Pushmatic breakers do not incorporate a magnetic sensor; therefore, they may not respond in the event of a short circuit. It is also important to note that Pushmatic breakers can become stiff over time due to their design, which relies on metal pivoting mechanisms instead of internal springs. For your safety, it is advisable to upgrade Pushmatic panels to modern electrical panels that conform to current safety standards.

Why Hire CSM?